The Terxon SX is the burglary alarm system made by ABUS Security-Center. The Terxon SX Full Kit with dialer contains all necessary components for effective, full-fledged protection. Changing the detectors and extending the system is possible at any time, as needed. The Terxon SX Full Kit with dialer provides you with all advantages of the Terxon SX. The system has 8 freely programmable zones for 8 wired detectors. Zone 9 is the tamper zone. Only NC detectors can be connected. The type of wiring is left up to you. The indoor sounder included in this kit has its own reserved zone on the motherboard. In addition to the alarm center, the heart of your system, the LCD control unit is also part of the full kit. The system can be programmed via the control unit and may be activated or deactivated via code or chip key. The connection is made via 4-wire bus wiring.
Art. no.: | AZ4350 |
Dimensions: | (WxHxD) 240x240x85 mm |
Connections: | 230 V screw terminal, loudspeaker, zone screwing terminal, transistor outputs, 13.8 V screw terminal |
Number of control devices: | 4 |
Number of control panels: | 4 |
Number of users: | 16 |
Number of wired zones: | 8 |
Number of events: | 250 |
Number of tamper zones: | 1 |
Display: | Two-line LCD alphanumerical display |
Outputs: | 3x transistors total, max. 500 mA, 8 x 50 mA, freely programmable |
Battery type: | 12V DC, 7.0 Ah lead rechargeable battery |
Width: | 240 mm |
Event log: | |
Housing material: | Alarm centre: Metal, control unit: ABS |
Height: | 240 mm |
Integrated siren: | |
Length: | 85 mm |
Max. number of control panels: | 4 |
Max. operating temperature: | 40 °C |
Max. battery charging time: | 24 h |
Max. humidity: | 75 % |
Max. run time on backup power: | 12 h |
Min. operating temperature: | -10 °C |
Net weight: | 3,3 kg |
Backup power supply: | |
Configuration (1): | Via control panel |
Tamper lines: | 2 |
Tamper monitoring: | |
Switching outputs: | 3 |
Security level: | 2 |
Fuse: | 230 V / 250 mA; 12 V: 1 A fast; rechargeable battery: 2 A fast |
Voltage monitoring: | |
AC voltage supply: | 230 V |
OSD language: | 11 selectable languages |
Power consumption: | 200 mA |
Partitions/surveillance partitions: | 4 |
Environmental class: | II |
Certifications: | INCERT, VSÖ, F&P, NCP |
Zone closure: | NC, DEOL |
Art. no.: | AZ4000 |
Dimensions: | (WxHxD) 240x240x85 mm |
Connections: | 230 V screw terminal, 13.8 V screw terminal, loudspeaker, zone-screw terminal, 11 x switching outputs |
Number of control panels: | 4 |
Number of users: | 16 |
Number of wired zones: | 8 |
Number of events: | 250 |
Number of tamper zones: | 1 |
Display: | Two-line LCD alphanumerical display |
Battery type: | 12V DC, 7.0 Ah lead rechargeable battery |
Width: | 240 mm |
Event log: | Yes |
Extensible (hybrid): | No |
Remote configuration: | No |
Housing material: | Alarm centre: Metal, control unit: ABS |
Height: | 240 mm |
Integrated siren: | Yes |
Communication/alarming: | Only compatible via external dialer: AZ6301, AZWG10020 |
Length: | 85 mm |
Max. number of control panels: | 4 |
Max. operating temperature: | 40 °C |
Max. battery charging time: | 24 h |
Max. humidity: | 75 % |
Max. run time on backup power: | 12 h |
Min. operating temperature: | -10 °C |
Net weight: | 2,45 kg |
Backup power supply: | Yes |
Configuration (1): | Via control panel |
Tamper lines: | 2 |
Tamper monitoring: | Yes |
Switching outputs: | 3 x 500 mA transistors, 8 x 50 mA transistors, freely programmable |
Security level: | 2 |
Fuse: | 230 V / 250 mA; 12 V: 1 A fast; battery: 2 A fast |
Voltage monitoring: | Yes |
AC voltage supply: | 230 V |
OSD language: | 11 selectable languages |
Power consumption: | 200 mA |
Partitions/surveillance partitions: | 4 |
Environmental class: | II |
Certifications: | INCERT |
Zone closure: | NC, DEOL |
Art. no.: | BT2070 |
Approval no.: | G 112110 |
Dimensions: | (WxHxD) 151x65x94 mm |
Rechargeable battery type: | Lead gel |
Width: | 151 mm |
Height: | 65 mm |
Capacity: | 7,2 |
Charging cycles: | up to 1000 |
Length: | 94 mm |
Net weight: | 2,54 kg |
DC voltage supply: | 12 V |
Certifications: | VdS |
Art. no.: | FU7350W |
VdS class: | none |
Dimensions: | (WxHxD) 11x12x48 mm |
Connections: | NC, max. contact capacity 100 V/5 W/0.05 A |
Width: | 11 mm |
Type of detection: | Magnetic field measurement |
Stray-field protection: | No |
Housing material: | ABS |
Height: | 12 mm |
Cable type: | 2-core |
Cable length: | 2 m |
Length: | 48 mm |
Installation location: | Integration / surface mounting |
Sensor type: | Read contact |
Art. no.: | AZ6301 |
Dimensions: | (WxHxD) 150x115x30 mm |
Connections: | Screw terminal for PSTN and power supply |
Number of voice messages: | 4 |
Display: | Illuminated segment display |
Type of inputs: | Positive/negative controllable inputs (5-28 V DC) |
Recording duration: | 0,0069444444444443 h |
Outputs: | 1 transistor output (OP), negative switching, max. current output 100 mA / 12 V DC per output |
Width: | 150 mm |
Inputs: | 4 |
Remote access: | Yes |
Housing material: | ABS |
Height: | 115 mm |
Compatible with: | Secoris, Secvest, Terxon |
Length: | 30 mm |
Max. operating temperature: | 55 °C |
Min. operating temperature: | -10 °C |
Net weight: | 0,36 kg |
Configuration (1): | Menu |
Tamper monitoring: | Yes |
IP protection class: | 32 |
Voltage monitoring: | Yes |
DC voltage supply: | 12 V |
Power consumption: | 35 mA |
Telephone number storage spaces: | 4 |
Transmission method: | Language |
Transmission path: | PSTN |
Art. no.: | SE1000 |
Dimensions: | (WxHxD) 114x85x42 mm |
Width: | 114 mm |
Housing material: | ABS |
Height: | 85 mm |
Compatible with: | Secoris, Secvest, Terxon |
Length: | 42 mm |
Power consumption: | 0,02 W |
Installation location: | Surface fitting |
Tamper monitoring: | Yes |
IP protection class: | 55 |
DC voltage supply: | 10-15 V |
Status display: | Yes (2 LEDs) |
Power consumption: | 2 mA |
Art. no.: | AZSG10020 |
Dimensions: | (WxHxD) 115x138x36 mm |
Width: | 119 mm |
Gross weight: | 0,212 kg |
Housing material: | POLYCARBONAT (PC) |
Height: | 41 mm |
Compatible with: | Secoris, Secvest, Terxon |
Length: | 145 mm |
Power consumption: | 1,2 W |
Illuminant: | LED |
Max. operating temperature: | 40 °C |
Max. humidity: | 95 % |
Min. operating temperature: | -15 °C |
Installation location: | Indoors |
Net weight: | 0,174 kg |
Tamper monitoring: | Yes |
Sound pressure: | 90 dB |
DC voltage supply: | 12 V |
Power consumption: | 100 mA |
Environmental class: | II |
Art. no.: | BW8010 |
Dimensions: | (WxHxD) 60x106x47 mm |
Alarm memory: | Yes |
Connections: | NC, 50 mA, 24 V DC |
Display: | Yes |
Width: | 60 mm |
Type of detection: | Heat detection |
Adjustable sensitivity: | Yes |
Detection range of detector (m): | 15 m |
Housing material: | ABS |
Height: | 107 mm |
Pulse selector: | Yes |
Length: | 47 mm |
Power consumption: | 0,12 W |
Max. operating temperature: | 55 °C |
Installation location: | Wall |
Net weight: | 0,08 kg |
Tamper monitoring: | Yes |
Sensor type: | Dual PIR |
DC voltage supply: | 12 V |
Status display: | Yes |
Power consumption: | 10 mA |
Creep zone: | Yes |
White light filter: | Yes |
Art. no.: | VT4000W |
VdS class: | C |
Approval no.: | G 105062 |
Dimensions: | (WxHxD) 115x40x19 mm |
Connections: | 16 double solder contacts |
Width: | 115 mm |
Housing material: | ABS |
Height: | 40 mm |
Length: | 19 mm |
Installation location: | Surface mounting |
Tamper monitoring: | Yes |
Environmental class: | III |
Certifications: | VdS C |