    TECTIQ Access Manager

    TECTIQ Access Manager

    TECTIQ locking system software: intuitively create locking and time schedules for door and person groups. Update or change access rights and much more.

    Description

    SIMPLE. ACCESS. ORGANISATION. WITH THE DIGITAL TECTIQ LOCKING SYSTEM.

    The TECTIQ Access Manager desktop software allows you to manage the entire TECTIQ access control system. You simply create permissions and can change them at any time by mouse click.

    Intuitive user interface with dashboard

    Here you can keep an eye on the system status and all parameters at all times. You can view upcoming updates and maintenance in the job list and easily delegate programming to the relevant employee using the TECTIQ Admin app.

    Time-saving software management

    Create, group or delete doors and persons. Efficiently block lost locking media and create replacement media. Set up schedules and locking days in the intuitive locking plan matrix for persons (groups). Implement property-specific processes and specifications efficiently and in compliance with the law (e.g. Works Council Mode, Office Mode).

    Simple data exchange

    Simply program, write and read locking media and system media on the desktop reader. Synchronisation between software and wirelessly integrated door components takes place via locking and system media.

    All-inclusive & secure access from anywhere

    The desktop software is part of every TECTIQ locking system. Up to 5 administrators can access the database from any computer in the same network. Remote access, even externally or across locations – with highly encrypted data transmission via a secure connection.

    TECTIQ Access Manager

    Product advantages

    • Desktop software for access management of the TECTIQ locking system for up to 5 administrators; flexible access from any PC
    • Convenient, flexible administration and maintenance of the TECTIQ system
    • Automated job list: the system automatically creates service orders for programming door components, e.g. using a parameter card
    • Intuitive dashboard for clear display of the system status, all parameters and open tasks for quick and easy operation
    • Flexible assignment of individual and group permissions for doors or door groups, as well as definition of specific individual authorisations
    • Locking plan matrix for organised display and easy management of all access authorisations for persons at access points (doors/persons) in a condensed and clear screen view
    • Simple creation of schedules and definition of blocking days for persons and groups of persons (incl. special permissions at person level)
    • Secure access to the TECTIQ database via LAN or remotely via an encrypted internet connection (online)
    • Flexible property-specific solutions, e.g. Office Mode (permanent opening), works council function
    • Simple configuration of door components, e.g. engagement time (opening time) of the TECTIQ cylinder

    Downloads

    Software:
    Installation software:

    Recycling

    We have summarised for you which disposal information is important in your country.

    Disposal & labelling of packaging

    Specifications
    Availability: Available for download at www.abus.com
    Compatible with: TECTIQ access control panel, TECTIQ update terminal, TECTIQ cylinder, TECTIQ narrow-frame fitting, TECTIQ wall reader, TECTIQ Admin app, TECTIQ system transponder, TECTIQ desktop reader USB
    Display resolution: Mindestens: 1440 x 1080 px, ideal: 1600 x 900 px
    Functions: Application and locking system software for the TECTIQ Data-on-Card locking system
    GDPR compliance: Yes, processing of data only for the provision of existing functionalities
    Initial installation: The application software can be installed on a PC/laptop via a setup file
    Internet connection: Internet connection required at regular intervals to refresh the online account token and to download firmware and software updates
    Item abbreviation: TEC-AM
    Network access: Local network connection between access control panel and administrator PC
    Number of SW accesses: Simultaneous access to a TECTIQ access control panel, installation of the Access Manager at any number of workstations possible
    Number of USB table readers: No limit
    Number of administrators: Creation of a maximum of 5 equally authorised administrators
    Number of offline door components: Max. 3.000
    Number of online update terminals: Max. 100
    Number of person groups: Max. 200
    Number of persons: Max. 2.000
    Registration: Creation of an ABUS online account, e.g. in the TECTIQ Access Manager
    Remote access: Peer-to-peer mediation server, firewall/port settings: recommended from port 40000 (UDP): P2P communication, alternatively: Port 53 (UDP): DNS Service, Port 443 (UDP/TCP) HTTPS base station connection, Port 3478 (UDP): STUN server connection, Port 3479 (UDP): STUN server connection, Port 5566 (UDP). Base station connection, Port 5568 (TCP): Gateway connection
    Security features: Login password protection, online verification token, including regular validity checks, password guidelines in accordance with GDPR, end-to-end encryption of the entire system
    Supported languages: German, English, Dutch, Swedish, Danish, Italian, French, Norwegian, Finnish
    Supported operating systems: Windows 10, Windows 11 (64-bit versions)
    System requirements: Processor: 2.0 GHz or faster, RAM: 2 GB or more, storage space: 2 GB or more
    Update capability: Auto-update in the application or via download from abus.com
    Version: 1.0.0