    Description

    The Terxon LX Hybrid Alarm Control Panel is the alarm system for commercial properties and larger building complexes. You can both integrate wired detectors and all Secvest 2WAY wireless components, thus extending the system to a hybrid system. The motherboard of the Terxon LX provides 8 freely programmable zones for 8 wired detectors. Each zone has its own tampering zone. Up to 128 control units and 32 extension modules can be connected via bus wiring, for 8 wireless zones or 8 wired zones. This way, you can extend the Terxon LX to 264 zones at any time. Additionally, the system can be split into 8 separately controlled sub-sections. The 23 switching outputs of the motherboard can be extended to a total of 93 outputs. If desired you can automatically switch the external devices that you have attached to these outputs (according to a specified schedule). Altogether, you can create 99 users in the system with 12 different authorization levels. The scope of delivery already includes an LCD keypad, allowing the system to be programmed or activated and deactivated. The system can also be programmed via PC (USB or RS232) or downloader software. Via the analogue telephone dialling unit (AWUG) already integrated in the system, you can notify an emergency call center in the event of an alarm. Thus, the Terxon LX hybrid alarm panel provides continuous all-round protection to the owner.

    For safe and proper operation, this device must be installed and regularly maintained by a professional trained by us. Arrange regular maintenance appointments with your installer to ensure trouble-free operation in the long term with the latest security updates and new functions.

    Product advantages

    • Hybrid system, scalable up to 256 wireless/wired zones
    • 8 partitions enable independent security for multiple building sections
    • Programming with LCD key pads or software
    • Integrated analogue dialler for transmitting digital monitoring centre protocols
    • Connect up to 128 control panels
    • High security because of tampered control panel, key pad, and detector

    Recycling

    We have summarised for you which disposal information is important in your country.

    Disposal & labelling of packaging

    Specifications
    AC power supply: 230 V
    Alarm generation: integrated analogue Dialer for transmission of digital ARC protocols
    Battery type: 12 V DC, 7.0 Ah or 17 Ah lead battery
    Communication/Alarming: Integrated analog dialer for transferring digital monitoring station protocols
    Connections: 230 V screw terminal, 13.8 V screw terminal, loudspeaker, zone-screw terminal, 23 x switching outputs, RS-232, PSTN, USB, 2 x bus
    Current consumption: 200 mA
    Depth: 90 mm
    Dimensions: (WxHxD) 390x310x90 mm
    Display type: Two-line LCD alphanumerical display
    Emergency power supply: Yes
    Environmental class: II
    Event memory: Yes
    Expandable (hybrid): Yes
    External interface: Yes
    Height: 310 mm
    Housing material: Alarm centre: Metal, keypad: ABS
    Integrated siren: No
    Language OSD: 11 selectable languages
    Length: 90 mm
    Max. Air humidity: 75 %
    Max. Battery charging time: 24 h
    Max. Emergency power runtime: 15 h
    Max. Max. number of detector groups: 264
    Max. Number of control units: 128
    Max. Operating temperature: 40 °C
    Mechanical protection: No
    Min. operating temperature: -10 °C
    Net weight: 4.9 kg
    Number of events: 2,000
    Number of operating elements: 128
    Number of sabotage detector groups: 8
    Number of tamper zones: 8
    Number of users: 99
    Number of wire zones: 8
    PSTI conformity needed: No
    Product group: Alarm panel
    Programming 1: Via control panel, per software, per modem
    Protocols: ARC: fast format, contact ID, SIA
    Radio networked: Yes
    Remote maintenance: Yes
    Security gradient: 2
    Security level: 230 V / 250 mA; 12 V: 1 A fast; rechargeable battery 2 A fast
    Sub-areas/monitoring areas: 8
    Switching outputs: 1 x siren, 1 x flash, 3 x 500 mA transistors, 2 x 1000 mA relays, 16 x 50 mA transistors
    Tamper lines: 9
    Tamper monitoring: 1
    VdS class: ohne
    Voltage monitoring: Yes
    WEEE group: 09
    Zone closure: NC / DEOL