Recently searched

    Terxon SX Alarm Control Panel
    Terxon SX Alarm Control Panel

    Terxon SX Alarm Control Panel - 2023

    The Terxon SX alarm control panel is the intruder alarm control panel for smaller properties from the ABUS Security Center.

    Description

    The Terxon SX alarm control panel is the intruder alarm control panel for smaller properties from the ABUS Security Center. Ten zones ensure seamless protection. The Terxon SX is the ideal entry-level model in the world of wired alarm technology. From condominiums to smaller commercial properties: This system gets to the heart of your security. Ten freely programmable zones for wired detectors are available to you during installation. The type of wiring - 2-wire CC, 4-wire CC or FSL in series or each as a separate zone - is up to you. A separate tamper zone is reserved for the signalling device on the main circuit board. Three transistor switching outputs with max. 500 mA switching capacity can be assigned to a specific event (alarm, fire, hold-up) and are also located on the main circuit board. If required, the Terxon SX can be extended with a relay board (eight relays with 3 A switching capacity). An elegant white LCD control panel is already included in the scope of delivery, which can be used to programme, activate or deactivate the system quickly and conveniently. You can connect four additional control panels. The connection is made via 4-wire bus wiring. 10 users with their own code can operate the system.

    Product advantages

    • Operation via LCD control panel
    • Optionally expandable with plug-in relay module
    • Compact housing
    • Tamper-monitored control panel, control unit and detector

    Recycling

    We have summarised for you which disposal information is important in your country.

    Disposal & labelling of packaging

    Specifications
    AC voltage supply: 230 V
    Alarming: Only via external diallers: AZ6301, AZWG10020
    Backup power supply: 1
    Battery - type: 12V DC, 7.0 Ah lead rechargeable battery
    Certifications: without
    Communication/alarm: Only compatible via external dialer: AZ6301, AZWG10020
    Connections: 230 V screw terminal, 13.7 V screw terminal, loudspeaker, zone-screw terminal, 11 x switching outputs
    Dimensions: (WxHxD) 250x239x87 mm
    Display: Two-line LCD alphanumerical display
    Environmental class: II
    Event memory: Yes
    Expandable (hybrid): No
    Fuse: 230 V / 250 mA; 12 V: 1 A fast; battery: 2 A fast
    Height: 239 mm
    Housing material: Alarm centre: Metal, control unit: ABS
    Integrated siren: No
    Length: 87 mm
    Max. backup power supply duration: 12 h
    Max. battery charging time: 72 h
    Max. humidity: 93 %
    Max. number of control units: 4
    Max. operating temperature: 55 °C
    Min. operating temperature: -10 °C
    Net weight: 2,8 kg
    Number of BUS lines: 1
    Number of control units: 4
    Number of events: 350
    Number of sabotage zones: 10
    Number of users: 10
    Number of wired zones: 10
    OSD language: 6 selectable languages
    PSTI conformity required: No
    Power consumption: 200 mA
    Programming 1: Via keypad
    Remote configuration: No
    Sabotage lines: 10
    Sabotage monitoring: Yes
    Sub-areas/monitoring areas: 4
    Switching outputs: 3 x 500 mA transistors, 8 x 50 mA transistors, freely programmable
    VdS class: without
    Voltage monitoring: Yes
    Width: 250 mm
    Zone closure: NC, DEOL
    Matching
     
     
     