Recently searched

    TECTIQ Controller Unit
    TECTIQ Controller Unit
    TECTIQ Controller Unit
    TECTIQ Controller Unit

    TECTIQ Controller unit update terminal Wi-Fi

    Controller unit update terminal Wi-Fi for use with TECTIQ readers. Used to validate and update access authorisations.

    Description

    EASY. ACCESS. ORGANISATION.

    With the digital TECTIQ locking system.

    The controller unit update terminal Wi-Fi serves as an update terminal when used in combination with the TECTIQ reader. In addition to the update function, the device can also control an actuator for authorisation, for example to open a turnstile. After a locking medium is presented, it is updated and authorisation is then checked. If authorisation is valid, the control unit activates the actuator so that the employee can, for example, pass through the turnstile after updating their locking medium.

    TECTIQ Update Terminal with access function

    The control unit synchronises the data of the TECTIQ access media with the access control centre during validation or updating. Data such as the validity and authorisations of the medium are updated. Secure continued operation is guaranteed even if the connection is lost: the most recently saved authorisation data is cached for a configurable period (network fallback). Up to 100 TECTIQ Update Terminals can be integrated into a single TECTIQ system across multiple sites via a secure internet connection.

    Maximum installation flexibility, secure control, efficient management

    Wi-Fi operation enables maximum flexibility and therefore cost-effective installation. The separate installation of the reader unit (e.g. at the gate) and the control unit indoors offers a high level of protection against tampering. The connection is made via the encrypted RS485 bus with a cable length of up to 250 m; the controller unit is not accessible from the outside.

    Set-up and programming are carried out conveniently via the Access Manager software. Data transfer, including firmware updates, can also be performed remotely via the internet (online).

    TECTIQ Controller Unit

    Product advantages

    • Controller unit update terminal Wi-Fi for operation with the TECTIQ reader, for validating and updating authorisations on access media, and for simultaneously controlling electronic door and gate drives as well as other actuators
    • Communication with the TECTIQ access control centre via Wi-Fi (2.4 GHz) for validating, updating and transferring authorisations, battery warnings, logs, etc.
    • Property-specific system solution with cross-site connection of up to 100 TECTIQ Update Terminals to the access control centre via a secure peer-to-peer connection
    • Secure continued operation in the event of a connection failure to the TECTIQ access control centre through temporary storage (configurable duration) of the latest authorisation data (network fallback)
    • Flexible relay configuration directly within the Access Manager software, easy adaptation to electronic actuators and the desired switching mode (NO, NO-pulse, NC, NC-pulse)
    • Activation of Office Mode for continuous control of actuators, e.g. for permanently open entrance gates during defined business hours
    • Remote mounting for maximum tamper protection, separate installation of controller and reader units with encrypted RS485 bus, up to 250 m cable length, control unit inaccessible from the outside
    • Compact installation by placing the reader unit directly onto the control unit installed in the flush-mounted box
    • Flexible installation in a flush-mounted box or in an IP-rated surface-mounted housing
    • Power supply via 12 V DC or, alternatively, PoE

    Recycling

    We have summarised for you which disposal information is important in your country.

    Disposal & labelling of packaging

    Specifications
    Air humidity: Max. 80 % relative humidity, non-condensing
    Areas of application: Activation of electronic door and access control systems (e.g. electric door opener, motorised locks, gate and barrier systems) and other actuators
    Article abbreviation: TEC-SG-WLAN
    Article program: TECTIQ
    Cable routing: Up to 100 m distance between control unit and Ethernet adapter, up to 250 m distance between control unit and reader unit (4 x 0.34 mm², shielded)
    Certifications: -
    Colour: white
    Communication protocols: TCP/IP, peer-to-peer mediation server
    Connections: Two plug-in connection terminals
    DC power supply: (terminal 1/connection 1 - 8) PoE IEEE 802.3af or (terminal 2/connection 13 - 14) external 12 V
    Default IP settings: DHCP
    Depth: 47 mm
    Ethernet interface: Terminal 1/connection 1 - 8 (see mounting instructions)
    Factory reset: Yes
    Failover network: Intermediate buffering of data and continued operation without a network connection for a predefined period of time (can be set on the software side)
    Height: 71 mm
    Inputs: 0
    Length: 47 mm
    Management: Access Manager Software
    Material: Plastic
    Max. Operating temperature: 60 °C
    Max. current: 100 mA/1.0 W (update terminal control unit without actuator/reader unit)
    Memory type: Circular buffer: 10,000 events
    Min. operating temperature: -20 °C
    Mounting type: Flush socket
    Net weight: 0.0707 kg
    Number of wall readers: One reader unit per control unit
    Opening time adjustable: Yes (1, 2, 4, 6, 8 or 12 s)
    PoE Standard: 802.3 af (PoE)
    Protection class IP: IP20
    RFID technology: No interface, operation via the reader unit
    RS-485 interface: Yes
    Radio encryption: WPA2, WPA3
    Radio frequency: 2,400 MHz
    Radio range: Open field: 70 m; indoors: typically 25 m
    Radio standard: IEEE 802.11g
    Real-time clock (RTC): Yes
    Relay configuration: Bistable relay: NO, NC, NO pulse, NC pulse
    Relay outputs: One potential-free relay output, dielectric strength: 60 V DC, 50 V AC, current carrying capacity: 1 A DC, 1 A AC
    Security features: End-to-end encrypted data transmission via RS485 between control unit and reader unit, separate installation of control unit and reader unit possible
    Special functions: Office Mode for permanent activation of the locking element, e.g. during business hours
    Time buffering Power failure: Max. 3 hours
    Transmission power: 100 mW / 20 dBm
    Update capability: Yes, via network
    Validation intervals: Freely configurable (in the TECTIQ Access Manager)
    VdS class: ohne
    signaling: Visual and optional acoustic signalling via the reader unit