    With T90 fire protection: electronic TECTIQ panic cylinder with RFID reader. The all-rounder in a variety of designs and lengths to replace mechanical profile cylinders. Elegant and robust.

    Description


    With the digital TECTIQ locking system.

    The electronic TECTIQ locking cylinder with RFID reader grants people access on the locking medium (transponder, card) according to their permission level. Data exchange is encrypted and protected against readout (MIFARE® DESFire®). The battery-operated door component requires no external cabling or radio connection.

    Validation/update
    ABUS TECTIQ stores permissions and events on the RFID locking medium (Data-on-Card) and exchanges data wirelessly with the cylinder or the system. The optical illuminated ring signals to users whether they are authorised to access the system.

    Elegant design, top quality
    With its clear design and knob cap (RFID reader unit) in black or grey, the robust, high-quality cylinder with IP67 and stainless steel look is suitable for any door and surface.

    Customised modular extension
    The double knob cylinder is suitable for exterior and interior doors with door leaves 30 to 90 mm thick on each side. Extension modules in 5 mm increments are used to adapt the length to individual conditions, including flexibly on site or for shaft extension for doors with core pull protection.

    Wide range of variants
    Available in different versions: with reader on the outside or on both sides (e.g. for connecting doors), as a double knob, half cylinder or padlock. With panic function for emergency exit doors (EN 179/EN 1125).

    Further options & configurations
    Fire protection: Standard T30 and optional T90; optional security drill protection with extra-reinforced anti-drill protection (SKG***) and core pull protection extension, e.g. for exterior and security doors.

    TECTIQ double knob cylinder, reader outside panic T90 TECTIQ double knob cylinder, reader outside panic T90

    Product advantages

    • Electronic TECTIQ double knob cylinder for secure yet simple and flexible installation on T90 fire doors that require a defined reset of the lock cam in accordance with EN 179/1125.
    • High-quality T90 panic cylinder (reader outside) with stainless steel outside knob and continuous stainless steel look, in a discreet, purist design line; highly weather-resistant in the standard version (IP67)
    • TECTIQ cylinder with RFID reader for secure, readout-protected Data exchange with TECTIQ locking media (MIFARE® DESFire®); with free-running exterior knob: no access without authentication
    • The cylinder can be programmed via Bluetooth with the TECTIQ Admin app and, for example, receive a new time or the latest firmware update
    • Elegant design in different Design variants to match the style of your building thanks to different colours and knobs
    • Suitable for any door leaf thickness: cylinder length can be individually adjusted from 30 to 90 mm on each side thanks to the modular extension concept (length of the configured cylinder can still be adjusted on site)
    • Replace the cylinder instead of the fitting set: convert a mechanical to an electronic cylinder at a favourable price and integrate the door into the TECTIQ locking system (simple cylinder replacement using a screw)
    • For installation in fittings with core pull protection or doors without profile perforation: optionally available with core pull protection extension (OPZ) to guide the outer shaft of the cylinder up to 10 mm through the fitting
    • For use in escape/rescue routes (EN 179/1125) – with defined reset of the lock cam
    • Tested, certified quality: EN 15684, SKG*** (SEC), fire protection T90

    Recycling

    We have summarised for you which disposal information is important in your country.

    Disposal & labelling of packaging

    Specifications
    Administration: TECTIQ Access Manager
    Area of application: Fireprotection doors with emergency exit according to EN 179/EN 1125 and locks that require a defined cam position
    Backset: ≥ 30 mm (round knob)/≥ 35 mm (square knob)
    Backup power supply: Yes, Micro USB
    Battery - runtime: At 20 °C (room temperature): up to 60,000 cycles or 3.5 years if not actuated
    Battery - type: VARTA Lithium battery 3V CR2/CR15H270/6206
    Battery compartment: In outer knob
    Battery warning stages: 2 levels
    Bluetooth version: 5.1
    Certifications: EN 15684:2020 1-6-B-4-x-D-3-A/D, optional SKG*** (with Security drilling protection)
    Colour: Outer knob: brushed stainless steel black or grey / Inner knob: brushed stainless steel / Cylinder body: brushed stainless steel
    Core pulling protection extension: Optional 10 mm (configuration feature)
    Corrosion protection: According to EN 1670 class 3/EN 15684 class 4
    Custom lengths: Yes, on request
    Cylinder profiles: Euro profile
    Design: Double knob cylinder
    Dimensions: External knob: L = 48 mm, Ø = 38 mm, internal knob: L = 27 mm, Ø = 33 mm
    Drill protection: Standard / Security (SKG***/EN 15684 clause 8 class D)
    Emergency variant in accordance with EN179 and 1125: Defined cam position
    Extension steps: 5 mm (modular)
    Factory reset: Yes
    Fatigue strength: > 200.000 cycles (EN 15684:2020 class 6)
    Fire protection class: T90
    Humidity: 20-99 % non-condensing according to EN 15684 class 4 %
    IP protection class: 67
    Inside knob variants: Square / Slim
    Item abbreviation: TEC-Z-LA-P-T90
    Material: Outer cap: stainless steel, plastic / Inner knob: stainless steel / Cylinder body: brass
    Max. blacklist number: 120
    Max. inside length: 90 mm
    Max. operating temperature: 65 °C
    Max. outside length: 90 mm
    Min. inside length: 35 mm
    Min. operating temperature: -25 °C
    Min. outside length: 30 mm
    Modularity: Yes
    Opening time can be set: Yes (6/12 Sec)
    Outside knob variants: Square / Round
    Programming: TECTIQ System Cards, TECTIQ Admin App
    Programming technology: RFID (13.56 MHz) / Bluetooth (2.4 GHz)
    RFID frequency: 13,56 MHz
    RFID range: ≤ 1 cm
    RFID technology: MIFARE® DESFire® EV1, EV2, EV3
    Real-time clock (RTC): Yes
    Security features: Freely rotating outside knob to prevent unauthorized access, engagement only when an authorised locking medium is presented, predetermined breaking point on outside knob, drilling protection
    Signalling: Visual
    Special functions: Office Mode
    Storage type: Ring memory: 890 events
    Transmission power: -4 dBm
    Transponder conformity: Passive-Transponder ISO 14443 A (MIFARE® DESFire®)
    Transponder encryption: AES 128-Bit
    Update capability: Yes (USB Updater Cable / Admin App)
    Use on escape and rescue routes: Yes, according to EN 179 and EN 1125, see lock compatibility list (mandatory)
    Variants: Drilling protection standard/security, core pull protection extension
    Wireless conformity: ETSI EN 300 328
    Wireless encryption: AES 128-Bit
    Wireless standard: Bluetooth Low Energy 2,4 GHz